A Worked Example: Concrete Stairs

One concrete stair flight worked end to end: readings, riser math, waist-plus-triangles volume, landing, allowance, and a supplier-rounded order, plus solid steps.

A construction worker in a yellow hard hat and high-visibility vest kneeling beside wooden formwork for a concrete stair…
Check the risers against the same figure and write every reading on the record before any calculation.

One concrete stair flight, one order record, every step shown. The stair below rises 63 in over 9 risers, runs 42 in wide, and ends in a landing. Follow the readings to the order and you can check each line against your own stair.

How much concrete does this stair flight need?

The flight needs 32.5348 ft3 by geometry, or 1.20 yd3 measured. The order is 1.50 yd3 after an 8 percent allowance and rounding up to the supplier 0.25 yd3 increment. The rest of this page shows each step so you can repeat it on your own stair.

What are the readings for this stair?

Take every reading finish to finish. Measure the waist thickness perpendicular from the soffit to the inner-corner line on the structural section, where each tread meets the next riser.

Field readings for the worked stair flight
ReadingValueWhat it fixes
Total rise63 in, finished floor to finished floorRiser count
Target riser height7 inRiser count
Going11 in, face to face, without nosing projectionTread layout and slope length
Waist thickness6 in, perpendicular to the soffitWaist volume
Stair width42 in, clear concrete width inside the formsVolume
Landing42 in x 48 in x 6 in thickLanding volume
Planning allowance8 percent, for form spread plus spillagePlanning volume
Supplier increment0.25 yd3Order volume

How do the risers work out?

Divide the total rise by the target riser height and round to a whole number. Then divide the total rise by that whole number to get the actual riser height. Every riser in the flight uses this one figure.

Riser count = total rise / target riser height, rounded to a whole number

Actual riser height = total rise / riser count

  1. Riser count: 63 / 7 = 9 risers.
  2. Actual riser height: 63 / 9 = 7.0 in.
  3. Tread count: 9 - 1 = 8. The top tread is the upper floor or landing, so it is not a separate step.
  4. Total going: 8 x 11 = 88 in.

Check the result against the IRC limits for dwellings: 7.0 in sits under the 7-3/4 in maximum riser height, and the variation is 0 because every riser uses the same 7.0 in figure, inside the 3/8 in variation limit. The minimum tread depth is 10 in, and the 11 in going clears it. The local adopted code edition governs the finished stair.

How do you get the flight volume?

Use the waist-plus-triangles method for a flight carried on a sloped slab. The waist is the sloped slab under the steps. The triangles are the step shapes above the inner-corner line.

Waist slope length = riser count x sqrt(actual riser height^2 + going^2)

Waist volume = waist slope length x waist thickness x stair width

One step triangle volume = 0.5 x actual riser height x going x stair width

Flight volume = waist volume + riser count x one step triangle volume

  1. Per-step slope: sqrt(7^2 + 11^2) = sqrt(170) = 13.0384 in.
  2. Waist slope length: 9 x 13.0384 = 117.3456 in = 9.7788 ft. The slope uses 9 goings (99 in), not the 88 in total going, because it runs from the bottom of the first riser to the top landing edge, one going past the last riser face.
  3. Waist volume: 9.7788 x 0.5 x 3.5 = 17.1129 ft3. The 0.5 ft is the 6 in waist thickness, and the 3.5 ft is the 42 in width.
  4. One triangle: 0.5 x 0.58333 x 0.91667 x 3.5 = 0.93576 ft3. The 0.58333 ft is the 7 in riser height, and the 0.91667 ft is the 11 in going.
  5. Triangles total: 9 x 0.93576 = 8.4219 ft3.
  6. Flight total: 17.1129 + 8.4219 = 25.5348 ft3.

What does the landing add?

Measure each landing as a rectangle and add it on its own line. Keep flights and landings separate when their widths or thicknesses differ.

  1. Landing: 42 x 48 x 6 = 12,096 in3 = 7.0 ft3.
  2. Measured volume: 25.5348 + 7 = 32.5348 ft3.
  3. In yards: 32.5348 / 27 = 1.20499, shown as 1.20 yd3.
  4. Metric cross-check: 32.5348 x 0.0283168 = 0.9213 m3. The flight alone is 25.5348 x 0.0283168 = 0.7231 m3.

How does the measured volume become an order?

Keep measured volume, allowance, supplier rounding, and order volume on separate lines. A reviewer must be able to reverse the record back to the field readings. NRMCA Concrete in Practice CIP 31 advises ordering about 4 to 10 percent more than the volumetric estimate. Pick a figure inside the band with a stated reason. Do not fold an allowance into the geometry, and round up only at the supplier increment step.

  1. Measured volume: 1.20499 yd3.
  2. Planning allowance: 8 percent, for form spread plus spillage on a small stair pour. 1.20499 x 1.08 = 1.30139, shown as 1.30 yd3.
  3. Supplier rounding: the supplier sells in 0.25 yd3 increments. The next increment above 1.30139 is 1.50 yd3.
  4. Result: order 1.50 yd3.
Order record for the worked stair flight
LineValueBasis
Measured volume1.20 yd332.5348 ft3 from the field readings
Planning allowance8 percentForm spread plus spillage, inside the NRMCA 4 to 10 percent band
Planning volume1.30 yd31.20499 x 1.08 = 1.30139
Supplier roundingUp to 0.25 yd3 incrementNext increment above 1.30139
Order volume1.50 yd3Confirm the supplier minimum and any short-load charge before booking

Enter the measured stair volume in known-volume mode in the Ready-Mix Concrete Calculator to check the planning volume and the supplier-rounded order.

How do solid steps on grade work out?

Use stacked rectangles for steps cast solid on the ground, such as porch steps with no open space below. Each step runs the full width and going, and its height grows by one riser per step.

Solid step k volume = stair width x going x (k x riser height)

The example below uses 4 steps at a 12 in going, a 6.5 in riser height, and a 60 in width.

Solid steps on grade, stacked-rectangle volumes
StepHeightVolume
Step 16.5 in60 x 12 x 6.5 = 4,680 in3 = 2.7083 ft3
Step 213 in60 x 12 x 13 = 9,360 in3 = 5.4167 ft3
Step 319.5 in60 x 12 x 19.5 = 14,040 in3 = 8.125 ft3
Step 426 in60 x 12 x 26 = 18,720 in3 = 10.8333 ft3
Total46,800 in3 = 27.0833 ft3 = 1.00309 yd3, shown as 1.00 yd3
  1. Measured volume: 1.00309 yd3.
  2. Planning allowance: 6 percent, for form spread plus spillage. 1.00309 x 1.06 = 1.06327, shown as 1.06 yd3.
  3. Supplier rounding: the next 0.25 yd3 increment above 1.06327 is 1.25 yd3.
  4. Result: order 1.25 yd3.

Do not apply waist plus triangles to solid steps. That method counts a sloped slab that does not exist in solid work.

Which cross-checks catch the common errors?

Run at least one cross-check before you call the supplier. Each check below targets one error that changes the order.

Cross-checks for a concrete stair calculation
CheckArithmeticError it catches
Waist slope by Pythagorassqrt(63^2 + 99^2) = 117.3456 in, matching the step-by-step slopeUsing total going (88 in) in the slope, which shortens the waist
Waist volume in cubic inches117.3456 x 6 x 42 = 29,571.1 in3 = 17.1129 ft3Unit slips between inches and feet
Triangle volume in cubic inches0.5 x 7 x 11 x 42 = 1,617 in3 = 0.93576 ft3Missing the 0.5 in the triangle formula
Metric cross-check32.5348 ft3 x 0.0283168 = 0.9213 m3A conversion or decimal error in the yardage
Tread count9 risers - 1 = 8 treads; 8 x 11 = 88 in total goingCounting 9 treads, which pushes the flight past the top landing edge
Order above measured volumeOrder 1.50 yd3 is above measured 1.20 yd3Rounding down at the supplier increment, or skipping the allowance

Safety and professional scope

Quantity planning does not design the stair, the formwork, the reinforcement, or the support. Those decisions follow the project drawings, specifications, local rules, and qualified people. The local adopted code edition governs the finished stair, and jobsite stairs follow the site safety rules.

Fresh concrete is caustic. Wear gloves, boots, and eye protection, and wash skin contact with clean water. For U.S. concrete formwork safety context, see OSHA 29 CFR 1926.703. Keep clear of the truck, the pump line, formwork loads, stored material, and edges. Work from a safe position and keep the discharge route clear.

Sources and scope

  • International Residential Code, Section R311.7.5.1 (risers) and R311.7.5.2 (treads): maximum riser height 7-3/4 in, riser variation within a flight at most 3/8 in, minimum tread depth 10 in, tread variation within a flight at most 3/8 in. The local adopted edition and amendments govern.
  • NRMCA, Concrete in Practice CIP 31, Ordering Ready Mixed Concrete: 4 to 10 percent ordering allowance band, small clean-up load caution under 4 cubic yards, ticket check and signing, agreed discharge time limit.
  • NIST Handbook 44, 2026 Appendix C: General Tables of Units of Measurement, including the exact definitions behind the conversions used here (1 ft = 12 in, so 1 ft3 = 1,728 in3; 1 yd = 3 ft, so 1 yd3 = 27 ft3; 1 ft3 = 0.0283168 m3).
  • OSHA 29 CFR 1926.703: U.S. concrete and masonry construction requirements, cited for formwork safety scope only.

Scope: this article works two examples end to end: one suspended concrete stair flight with a landing, and one set of solid steps on grade. The governing drawings, specifications, safety plan, supplier records, applicable law, and responsible qualified people control the specified mix, reinforcement, formwork, finish, curing, and final order quantity.

Review responsibility: Saleem Sial owns the published calculation, source, and editorial checks. Waseem Sial, External Reviewer and Engineer, remains listed for ongoing external review; no completed external-review date is claimed.

Next, measure your own flight with the concrete stair measurement guide, choose the mix with the concrete stair mix guide, order it with the concrete stair ordering guide, check the twelve errors with the concrete stairs mistakes guide, run the numbers in the Concrete Stairs Calculator, or return to the Concrete Calculators hub.